Legislation Details

File #: 26-312    Version: 1
Type: New Business Status: Agenda Ready
File created: 5/6/2026 Meeting Body: Planning & Zoning Commission
On agenda: 5/12/2026 Final action:
Title Search: PUBLIC HEARING: Consider a request for a Specific Use Permit (SUP) with a variance for an existing 768 square-foot detached garage with an approximate average height of 18 feet, located on 0.81 acres, on the north side of Meadowview Drive, approximately 1058 feet northeast of the intersection of North Pearson Lane and Meadowview Drive, legally described as Lot 1, Block A of the Agape Acres subdivision, zoned Single-Family 20,000 square-foot lot size or greater (SF-20) and addressed 2101 Meadowview Drive. David and Kayla Andriese, Applicant/Owner. (SUP-2604-0010)
Attachments: 1. 051226_2101 Meadowview SUP_Maps, 2. 051226_2101 Meadowview SUP_Applicant packet

To:                     Planning and Zoning Commission

From:                     Alexis Zimmerman, Planner II

Subject:                     

Title

PUBLIC HEARING: Consider a request for a Specific Use Permit (SUP) with a variance for an existing 768 square-foot detached garage with an approximate average height of 18 feet, located on 0.81 acres, on the north side of Meadowview Drive, approximately 1058 feet northeast of the intersection of North Pearson Lane and Meadowview Drive, legally described as Lot 1, Block A of the Agape Acres subdivision, zoned Single-Family 20,000 square-foot lot size or greater (SF-20) and addressed 2101 Meadowview Drive. David and Kayla Andriese, Applicant/Owner. (SUP-2604-0010)

Body

 

Background:

The Applicant requests a Specific Use Permit (SUP) to be allowed to retain a 768 square-foot detached garage with an average height of 18 feet.

 

The detached garage was partially constructed without an approved building permit. The basic timeline is as follows:

 

                     February 2025: Applicant submitted a building permit for the detached garage (RDA-2502-0022) However, the submittal was incomplete.

                     May 2025: A code case was opened for a structure being built without a permit (CODE-2505-0249) and a Stop Work Order was issued.

                     June - August 2025: Staff had conversations with the building contractor about the missing paperwork for the building permit.

                     August 2025: Missing documents were received, and the building permit was sent for staff review.

                     August 2025 - January 2026: Multiple rounds of review and revision requests were conducted in which staff requested clarification of building height and for an engineered grading plan.

                     February 2026: Applicant was informed that the building would require SUP approval for the average height of the building to exceed 15 feet.

                     April 2026: SUP application was submitted.

 

The detached garage is to be used for storage, lawn equipment, and for the property owner’s personal vehicles.

 

Site Design:

The proposed site plan shows the structure is located behind the existing home and will conform to the setback requirements of the SF-20 zoning district.

 

The structure is located approximately 108 feet from the front, 15 feet from the east side property line, and 18 feet from the rear property line.

 

Elevations:

The detached garage was designed to match the materials of the main home on the property and is constructed of white siding and a shingle roof.

 

UDC Section 9.06 (A)(9) states that the maximum height of an accessory building shall not exceed fifteen feet (15') unless approved by a SUP for additional height.

 

The structure is located 5 feet below the elevation of the main home. The street view of the structure appears to show a peak height of 15 feet 2 inches.

 

However, per Section 9.06 of the UDC, building height is calculated from the lowest point of the building to the average of the highest and lowest points of the roof. The average height of the structure is approximately 18 feet; measured from the average of the base plate and the peak (20 feet 2 inches) of the roof.

 

Existing structures:

The main home is approximately 2,855 square-feet. The UDC states that the combined area of all accessory buildings on a lot shall be less than 50% of the main structure, unless approved by an SUP.

 

There are two other accessory structures on the lot: an approximately 240 square-foot shed and an approximately 130 square-foot covered chicken coop. The Applicant is requesting a variance to allow for more than 2 accessory structures on the lot.

 

The combined square-footage of all accessory structures on the lot is less than 50% of the square-footage of the main structure.

 

Request:

1.                     An SUP for the height of the structure to exceed an average of 15 feet tall. The proposed average height is 18 feet.

2.                     A variance to allow for more than 2 accessory structures on the property.

 

Summary:

Section 8.02 (F)(2)(a) of the UDC states that when considering a SUP request, the Planning and Zoning Commission and City Council shall consider the following factors:

 

1)                     The use is harmonious and compatible with surrounding existing uses or proposed uses;

 

2)                     The activities requested by the applicant are normally associated with the permitted uses in the base district;

 

3)                     The nature of the use is reasonable and appropriate in the immediate area;

 

4)                     Any negative impact on the surrounding area has been mitigated; and

 

5)                     That any additional conditions specified ensure that the intent of the district purposes are being upheld.

 

Citizen Input:

On April 30, 2026, the City mailed 24 Letters of Notification for this public hearing to all property owners within three-hundred feet (300’) of the subject site. A public hearing notice sign was also posted on the site.

 

Staff has received no public opinion letters in response to this request.

                    

Alternatives:

The Planning and Zoning Commission has the following options when considering Specific Use Permit requests:

 

                     Recommend approval as submitted.

                     Recommend approval with modified or additional condition(s).

                     Table the agenda item to a specific date with clarification of intent and purpose.

                     Recommend denial.

                     

City Council Action:

If the Planning and Zoning Commission takes action and makes a recommendation on this agenda item, this Specific Use Permit application will be scheduled for City Council action on June 2, 2026.